6/30KV 1, 3Core CU(AL)/XLPE/CTS/PVC Power Cable(N2XSY,NA2XSY)

Aluminum or Copper Conductor, XLPE insulated, Copper Tape screened, PVC sheathed; Voltage:3.6/6kv,6/10kv,8.7/15kv,12/20kv,18/30kv; Standard: IEC60502-2, BS, ICEA, AS/NZS, VDE and other standards.

We're here to help:Easy ways to get the answers you need.

  • Description
  • Parameter
Application:
1.The max. rated temp. of the cable’s conductor is 90˚C.
2.Max. short circuit temp. of the cable’s conductor shall not exceed 250˚C. (max. duration not exceed 5s)
3.For easily to choose cable, the system is divided into three categories:
A category: Any phase can separate from the system in 1 minute when earthing or earthing conductor.
B category: when the single-phase is earthed can be operated short-time according to the provision of IEC 60183, the fault duration does not exceed 1 hour for cable in line with the standards, the earth fault duration is longer and does not exceed 8 hours under any circumstance, the accumulated time shall not exceed 125 hours each year.
C category: which does not belong to A or B category.
The values of U 0 recommended for cables to be used in three-phase systems are listed in
Table 1.
4. The ambient temp. shall not be lower than 0℃ during laying. Refer to Table 2 about the minimum bending radius:
Table 1

Highest system voltage (U m) /kV

Rated voltage (U 0) /kV

Categories A and B

Category C

7.2

3.6

6.0

12.0

6.0

8.7

17.5

8.7

12.0

24.0

12.0

18.0

36.0

18.0

_


Table 2

Items

Single-core Cables

Three-core Cables

Unarmored

Armored

Unarmored

Armored

Min. bending radius during installation

20D

15D

15D

12D

Min. bending radius close to connection box and termination (bending radius should be controlled carefully, if the molding guide plate is used)

15D

12D

12D

10D


 
Construction :
Single / Three Core:
1.Aluminum Conductor or copper conductor
2.Conductor shield
3.XLPE insulation
4.Insulation shield
5.Copper tape shield
6.PVC or PE outer sheath


Specifications:
The cables are manufactured according to IEC60502-2, BS, ICEA, AS/NZS, VDE and other standards.
 
YJV/YJLV 1 CORE 3.6/6KV    (N2XSY,NA2XSY)
Nominal cross 
sectional area
Insulation 
thickness
Copper tape
 thickness
Sheath 
thickness
Approximate 
outer diameter
Approx.weight 
kg/km
Max. DC Resistance 
at 20℃ Ω/km
mm2 mm mm mm mm CU AL CU AL
1X10 2.5 0.12 1.8 16.2 356 294 1.83 3.08
1X16 2.5 0.12 1.8 17.0 428 330 1.15 1.91
1X25 2.5 0.12 1.8 18.2 537 383 0.727 1.20
1X35 2.5 0.12 1.8 19.2 647 434 0.524 0.868
1X50 2.5 0.12 1.8 20.3 787 497 0.387 0.641
1X70 2.5 0.12 1.8 22.0 1008 593 0.268 0.443
1X95 2.5 0.12 1.8 23.8 1285 707 0.193 0.320
1X120 2.5 0.12 1.8 25.0 1534 803 0.153 0.253
1X150 2.5 0.12 1.8 26.5 1818 911 0.124 0.206
1X185 2.5 0.12 1.9 28.4 2195 1064 0.0991 0.164
1X240 2.6 0.12 1.9 30.9 2755 1289 0.0754 0.125
1X300 2.8 0.12 2.0 33.7 3400 1548 0.0601 0.100
1X400 3.0 0.12 2.2 37.2 4330 1921 0.0470 0.0778
1X500 3.2 0.12 2.3 40.9 5340 2332 0.0366 0.0605
1X630 3.2 0.12 2.4 44.8 6733 2836 0.0283 0.0469
YJV/YJLV 3 CORE 3.6/6KV    (N2XSY,NA2XSY)
Nominal cross 
sectional area
Insulation 
thickness
Copper tape
 thickness
Sheath 
thickness
Approximate 
outer diameter
Approx.weight 
kg/km
Max. DC Resistance 
at 20℃ Ω/km
mm2 mm mm mm mm CU AL CU AL
3X10 2.5 0.1 1.9 30.7 1003 816 1.83 3.08
3X16 2.5 0.1 2.0 32.6 1230 934 1.15 1.91
3X25 2.5 0.1 2.1 35.4 1566 1103 0.727 1.20
3X35 2.5 0.1 2.2 37.8 1910 1268 0.524 0.868
3X50 2.5 0.1 2.3 40.4 2429 1555 0.387 0.641
3X70 2.5 0.1 2.4 44.2 3111 1857 0.268 0.443
3X95 2.5 0.1 2.5 48.3 4023 2281 0.193 0.320
3X120 2.5 0.1 2.6 51.1 4795 2590 0.153 0.253
3X150 2.5 0.1 2.7 54.6 5719 2986 0.124 0.206
3X185 2.5 0.1 2.8 58.4 6845 3437 0.0991 0.164
3X240 2.6 0.1 3.0 64.2 8682 4262 0.0754 0.125
3X300 2.8 0.1 3.2 70.2 10756 5173 0.0601 0.100
3X400 3.0 0.1 3.5 77.5 13679 6416 0.0470 0.0778
3X500 3.2 0.1 3.7 85.5 16845 7777 0.0366 0.0605
3X630 3.2 0.1 3.9 93.9 21204 9455 0.0283 0.0469
YJV/YJLV 1 CORE 6/10kV    (N2XSY,NA2XSY)
Nominal cross 
sectional area
Insulation 
thickness
Copper tape
 thickness
Sheath
 thickness
Approximate
 outer diameter
Approx.weight 
kg/km
Max. DC Resistance 
at 20℃ Ω/km
mm2 mm mm mm mm CU AL CU AL
1X16 3.4 0.12 1.8 19.0 495 397 1.15 1.91
1X25 3.4 0.12 1.8 20.2 608 454 0.727 1.20
1X35 3.4 0.12 1.8 21.2 721 508 0.524 0.868
1X50 3.4 0.12 1.8 22.3 864 574 0.387 0.641
1X70 3.4 0.12 1.8 24.0 1091 675 0.268 0.443
1X95 3.4 0.12 1.8 25.8 1373 795 0.193 0.320
1X120 3.4 0.12 1.8 27.0 1626 894 0.153 0.253
1X150 3.4 0.12 1.9 28.7 1927 1021 0.124 0.206
1X185 3.4 0.12 1.9 30.4 2297 1167 0.0991 0.164
1X240 3.4 0.12 2.0 32.9 2869 1406 0.0754 0.125
1X300 3.4 0.12 2.1 35.3 3499 1648 0.0601 0.100
1X400 3.4 0.12 2.2 38.2 4396 1993 0.0470 0.0778
1X500 3.4 0.12 2.3 41.5 5384 2376 0.0366 0.0605
1X630 3.4 0.12 2.4 45.4 6782 2884 0.0283 0.0469
YJV/YJLV 3 CORE 6/10KV    (N2XSY,NA2XSY)
Nominal cross 
sectional area
Insulation 
thickness
Copper tape 
thickness
Sheath 
thickness
Approximate 
outer diameter
Approx.weight 
kg/km
Max. DC Resistance
 at 20℃ Ω/km
mm2 mm mm mm mm CU AL CU AL
3X16 3.4 0.1 2.1 37.2 1519 1223 1.15 1.91
3X25 3.4 0.1 2.2 39.9 1870 1406 0.727 1.20
3X35 3.4 0.1 2.3 42.3 2226 1584 0.524 0.868
3X50 3.4 0.1 2.4 44.9 2675 1801 0.387 0.641
3X70 3.4 0.1 2.5 48.8 3437 2184 0.268 0.443
3X95 3.4 0.1 2.7 53.0 4333 2591 0.193 0.320
3X120 3.4 0.1 2.8 55.8 5167 2961 0.153 0.253
3X150 3.4 0.1 2.9 59.3 6064 3332 0.124 0.206
3X185 3.4 0.1 3.0 63.1 7302 3894 0.0991 0.164
3X240 3.4 0.1 3.2 68.5 9152 4732 0.0754 0.125
3X300 3.4 0.1 3.3 73.5 11150 5567 0.0601 0.100
3X400 3.4 0.1 3.5 79.7 13880 6616 0.0470 0.0778
3X500 3.4 0.1 3.7 86.8 16979 7913 0.0366 0.0605
3X630 3.4 0.1 4.0 95.4 21394 9646 0.0283 0.0469
YJV/YJLV 1 CORE 8.7/15kV    (N2XSY,NA2XSY)
Nominal cross
 sectional area
Insulation
 thickness
Copper tape
 thickness
Sheath 
thickness
Approximate 
outer diameter
Approx.weight 
kg/km
Max. DC Resistance
 at 20℃ Ω/km
mm2 mm mm mm mm CU AL CU AL
1X25 4.5 0.12 1.8 22.4 691 538 0.727 1.20
1X35 4.5 0.12 1.8 23.4 808 595 0.524 0.868
1X50 4.5 0.12 1.8 24.5 955 665 0.387 0.641
1X70 4.5 0.12 1.8 26.2 1187 772 0.268 0.443
1X95 4.5 0.12 1.9 28.2 1488 910 0.193 0.320
1X120 4.5 0.12 1.9 29.4 1746 1014 0.153 0.253
1X150 4.5 0.12 2.0 31.1 2053 1147 0.124 0.206
1X185 4.5 0.12 2.0 32.8 2430 1300 0.0991 0.164
1X240 4.5 0.12 2.1 35.3 3011 1548 0.0754 0.125
1X300 4.5 0.12 2.2 37.7 3650 1799 0.0601 0.100
1X400 4.5 0.12 2.3 40.6 4559 2157 0.0470 0.0778
1X500 4.5 0.12 2.4 43.9 5559 2553 0.0366 0.0605
1X630 4.5 0.12 2.5 47.8 6971 3076 0.0283 0.0469
YJV/YJLV 3 CORE 8.7/15KV    (N2XSY,NA2XSY)
Nominal cross 
sectional area
Insulation
 thickness
Copper tape
 thickness
Sheath 
thickness
Approximate
 outer diameter
Approx.weight 
kg/km
Max. DC Resistance 
at 20℃ Ω/km
mm2 mm mm mm mm CU AL CU AL
3X25 4.5 0.1 2.4 45.1 2154 1691 0.727 1.20
3X35 4.5 0.1 2.5 47.5 2524 1883 0.524 0.868
3X50 4.5 0.1 2.6 50.0 3049 2175 0.387 0.641
3X70 4.5 0.1 2.7 53.9 3773 2520 0.268 0.443
3X95 4.5 0.1 2.8 58.0 4714 2972 0.193 0.320
3X120 4.5 0.1 2.9 60.8 5608 3403 0.153 0.253
3X150 4.5 0.1 3.0 64.2 6524 3792 0.124 0.206
3X185 4.5 0.1 3.2 68.3 7829 4421 0.0991 0.164
3X240 4.5 0.1 3.3 73.5 9678 5257 0.0754 0.125
3X300 4.5 0.1 3.5 78.6 11632 6049 0.0601 0.100
3X400 4.5 0.1 3.7 84.8 14489 7226 0.0470 0.0778
3X500 4.5 0.1 3.9 91.9 17660 8597 0.0366 0.0605
3X630 4.5 0.1 4.1 100.3 21960 10213 0.0283 0.0469
YJV/YJLV 1 CORE 12/20kV    (N2XSY,NA2XSY)
Nominal cross
 sectional area
Insulation
 thickness
Copper tape 
thickness
Sheath 
thickness
Approximate 
outer diameter
Approx.weight 
kg/km
Max. DC Resistance
 at 20℃ Ω/km
mm2 mm mm mm mm CU AL CU AL
1X35 5.5 0.12 1.8 25.8 914 701 0.524 0.868
1X50 5.5 0.12 1.8 26.9 1065 775 0.387 0.641
1X70 5.5 0.12 1.9 28.8 1317 901 0.268 0.443
1X95 5.5 0.12 1.9 30.6 1612 1035 0.193 0.320
1X120 5.5 0.12 2.0 32.0 1889 1157 0.153 0.253
1X150 5.5 0.12 2.0 33.5 2189 1282 0.124 0.206
1X185 5.5 0.12 2.1 35.4 2588 1457 0.0991 0.164
1X240 5.5 0.12 2.2 37.9 3180 1717 0.0754 0.125
1X300 5.5 0.12 2.2 40.1 3812 1960 0.0601 0.100
1X400 5.5 0.12 2.3 43.0 4731 2329 0.0470 0.0778
1X500 5.5 0.12 2.4 46.3 5744 2739 0.0366 0.0605
1X630 5.5 0.12 2.5 50.2 7172 3276 0.0283 0.0469
YJV/YJLV 3 CORE 12/20KV    (N2XSY,NA2XSY)
Nominal cross 
sectional area
Insulation
 thickness
Copper tape 
thickness
Sheath
 thickness
Approximate outer
 diameter
Approx.weight 
kg/km
Max. DC Resistance 
at 20℃ Ω/km
mm2 mm mm mm mm CU AL CU AL
3X35 5.5 0.1 2.7 53.0 2948 2306 0.524 0.868
3X50 5.5 0.1 2.8 55.6 3475 2601 0.387 0.641
3X70 5.5 0.1 2.9 59.5 4224 2971 0.268 0.443
3X95 5.5 0.1 3.0 63.6 5237 3495 0.193 0.320
3X120 5.5 0.1 3.1 66.4 6059 3853 0.153 0.253
3X150 5.5 0.1 3.2 69.8 7103 4371 0.124 0.206
3X185 5.5 0.1 3.3 73.7 8297 4888 0.0991 0.164
3X240 5.5 0.1 3.5 79.0 10212 5792 0.0754 0.125
3X300 5.5 0.1 3.6 84.0 12252 6670 0.0601 0.100
3X400 5.5 0.1 3.9 90.4 15219 7956 0.0470 0.0778
3X500 5.5 0.1 4.1 97.5 18466 9407 0.0366 0.0605
3X630 5.5 0.1 4.3 105.9 22821 11077 0.0283 0.0469
YJV/YJLV 1 CORE 18/30kV    (N2XSY,NA2XSY)
Nominal cross 
sectional area
Insulation
 thickness
Copper tape
 thickness
Sheath 
thickness
Approximate outer
diameter
Approx.weight 
kg/km
Max. DC Resistance
 at 20℃ Ω/km
mm2 mm mm mm mm CU AL CU AL
1X50 8.0 0.12 2.0 32.3 1346 1056 0.387 0.641
1X70 8.0 0.12 2.0 34.0 1599 1183 0.268 0.443
1X95 8.0 0.12 2.1 36.0 1925 1347 0.193 0.320
1X120 8.0 0.12 2.1 37.2 2197 1465 0.153 0.253
1X150 8.0 0.12 2.2 38.9 2526 1620 0.124 0.206
1X185 8.0 0.12 2.2 40.6 2924 1793 0.0991 0.164
1X240 8.0 0.12 2.3 43.1 3536 2075 0.0754 0.125
1X300 8.0 0.12 2.4 45.5 4206 2355 0.0601 0.100
1X400 8.0 0.12 2.5 48.4 5151 2751 0.0470 0.0778
1X500 8.0 0.12 2.6 51.7 6192 3189 0.0366 0.0605
1X630 8.0 0.12 2.7 55.6 7653 3759 0.0283 0.0469
YJV/YJLV 3 CORE 18/30KV    (N2XSY,NA2XSY)
Nominal cross 
sectional area
Insulation
 thickness
Copper tape 
thickness
Sheath
 thickness
Approximate outer
 diameter
Approx.weight 
kg/km
Max. DC Resistance
 at 20℃ Ω/km
mm2 mm mm mm mm CU AL CU AL
3X50 8.0 0.1 3.1 67.0 4528 3654 0.387 0.641
3X70 8.0 0.1 3.2 70.9 5326 4072 0.268 0.443
3X95 8.0 0.1 3.4 75.2 6439 4696 0.193 0.320
3X120 8.0 0.1 3.5 78.0 7298 5092 0.153 0.253
3X150 8.0 0.1 3.6 81.4 8372 5639 0.124 0.206
3X185 8.0 0.1 3.7 85.3 9615 6207 0.0991 0.164
3X240 8.0 0.1 3.8 90.4 11576 7155 0.0754 0.125
3X300 8.0 0.1 4.0 95.6 13781 8199 0.0601 0.100
3X400 8.0 0.1 4.2 101.8 16668 9405 0.0470 0.0778
3X500 8.0 0.1 4.4 108.9 20005 10953 0.0366 0.0605
3X630 8.0 0.1 4.7 117.5 24517 12778 0.0283 0.0469