products
  • 0.6/1kV Copper conductor XLPE Insulated Steel Wire armoured PVC Sheathed Control Cable(N2XRGbY)
  • 0.6/1kV Copper conductor XLPE Insulated Steel Wire armoured PVC Sheathed Control Cable(N2XRGbY)

0.6/1kV CU/XLPE/SWA/PVC Control Cable(N2XRGbY)

Copper conductor XLPE Insulated Steel Wire armoured PVC Sheathed; Standard: IEC60502,IEC 60228 or other standard can customized.

We're here to help:Easy ways to get the answers you need.

  • Description
  • Parameter

Application:

The control cable is used as the connecting line between all kinds of electrical appliances, meters and automatic devices. It is mainly used for AC rated voltage 600/1000V and under control, monitoring circuit and protection circuit.

Construction 

1)Conductor : Copper ,Class 1 or Class 2,solid or stranded Circular conductors  

2)Insulation: Cross-linked polyethylene XLPE

3)Filler: Non-hygroscopic material

4)Binder tape: Non-hygroscopic material

5)Inner covering: Polyvinyl chloride PVC

6)Armour: Steel wire armour

7)Binder tape: Non-hygroscopic material

8)Oversheath: Polyvinyl chloride PVC

 

 

Standard:

IEC 60228 Conductors of insulate cables

IEC 60502-1 Power cables with extruded insulation and their accessories for rated voltages from 1 kV(Um=1.2kV) up to 30kV(Um=36kV) - Part 1:Cables for rated voltages of 1 kV (Um=1.2kV) and 3 kV (Um=3.6kV)

No. of cores and nominal cross section

Thickness of Insulation

Diameter 

of Steel wire

Thickness of

 Sheath

Approx.

overall Diameter

Approx. weight

Max. DC resistance of conductor20

(mm2)

(mm)

(mm)

(mm)

(mm)

(kg/km)

(Ω/km)

KYJV32 (N2XRGbY) - 0.6/1kV

2X1.5

0.7

0.8

1.8

13.7

321

12.1

3X1.5

0.7

0.8

1.8

15.8

366

12.1

4X1.5

0.7

0.8

1.8

16.5

408

12.1

5X1.5

0.7

0.8

1.8

17.3

452

12.1

7X1.5

0.7

0.8

1.8

18.1

511

12.1

10X1.5

0.7

1.25

1.8

22.7

797

12.1

12X1.5

0.7

1.25

1.8

23.1

848

12.1

14X1.5

0.7

1.25

1.8

23.8

916

12.1

16X1.5

0.7

1.25

1.8

24.6

986

12.1

19X1.5

0.7

1.25

1.8

25.4

1070

12.1

24X1.5

0.7

1.6

1.8

29.6

1416

12.1

27X1.5

0.7

1.6

1.8

30.1

1493

12.1

30X1.5

0.7

1.6

1.8

30.8

1575

12.1

37X1.5

0.7

1.6

1.8

32.4

1774

12.1

44X1.5

0.7

1.6

1.9

35.4

2061

12.1

48X1.5

0.7

1.6

1.9

35.8

2135

12.1

52X1.5

0.7

1.6

2.0

36.7

2267

12.1

61X1.5

0.7

2.0

2.0

40.4

2796

12.1

2X2.5

0.7

0.8

1.8

16.1

381

7.41

3X2.5

0.7

0.8

1.8

16.6

423

7.41

4X2.5

0.7

0.8

1.8

17.4

477

7.41

5X2.5

0.7

0.8

1.8

18.3

538

7.41

7X2.5

0.7

1.25

1.8

21.1

744

7.41

10X2.5

0.7

1.25

1.8

24.3

964

7.41

12X2.5

0.7

1.25

1.8

24.8

1035

7.41

14X2.5

0.7

1.25

1.8

25.6

1125

7.41

16X2.5

0.7

1.6

1.8

27.9

1356

7.41

19X2.5

0.7

1.6

1.8

28.8

1484

7.41

24X2.5

0.7

1.6

1.8

32

1735

7.41

27X2.5

0.7

1.6

1.8

32.5

1840

7.41

30X2.5

0.7

1.6

1.9

33.6

1967

7.41

37X2.5

0.7

1.6

1.9

35.4

2252

7.41

No. of cores and nominal cross section

Thickness of Insulation

Diameter 

of Steel wire

Thickness of

 Sheath

Approx.

overall Diameter

Approx. weight

Max. DC resistance of conductor20

(mm2)

(mm)

(mm)

(mm)

(mm)

(kg/km)

(Ω/km)

KYJV32 (N2XRGbY) - 0.6/1kV

44X2.5

0.7

2.0

2.1

41

2917

7.41

48X2.5

0.7

2.0

2.1

41.5

3056

7.41

52X2.5

0.7

2.0

2.1

42.3

3205

7.41

61X2.5

0.7

2.0

2.2

44.4

3581

7.41

2X4

0.7

0.8

1.8

17

427

4.61

3X4

0.7

0.8

1.8

17.6

483

4.61

4X4

0.7

0.8

1.8

18.6

556

4.61

5X4

0.7

1.25

1.8

21.4

761

4.61

7X4

0.7

1.25

1.8

22.5

886

4.61

10X4

0.7

1.6

1.8

27.5

1283

4.61

12X4

0.7

1.6

1.8

28.1

1390

4.61

14X4

0.7

1.6

1.8

29.1

1521

4.61

16X4

0.7

1.6

1.8

30.1

1656

4.61

19X4

0.7

1.6

1.8

31.2

1826

4.61

24X4

0.7

1.6

1.9

35

2224

4.61

27X4

0.7

1.6

1.9

35.6

2374

4.61

30X4

0.7

1.6

2.0

36.8

2564

4.61

37X4

0.7

2.0

2.1

41.1

3261

4.61

44X4

0.7

2.0

2.2

44.9

3769

4.61

48X4

0.7

2.0

2.2

45.5

3965

4.61

52X4

0.7

2.0

2.3

46.6

4221

4.61

61X4

0.7

2.0

2.3

48.8

4713

4.61

*Describe Your Buying Requirements in Detail